Supply Air Handling Units – Selection Guideelection Guide
                                               Supply Air Handling Units – S




                                                  ERP 2018 = SFP<1,1          Amps                   KW              Weight             Dimensions (mm)           +Length
          Unit Configuration        Model Ref  Min Capacity l/s Max Capacity l/s  1 x 240V  3 x 400V  1 x 240V  3 x 400V  (kg)   Length      Depth       Height  with 1 coil
                                    VEX5020S       300       1095                   9,3(11)              2,46(3,39)  311(322)     2957       1027        767        Inc
                                    VEX5050S       500       2150                  11,9(12)              3,93(3,99)  494(526)     3277       1417        1017       Inc
                                    VEX5080S       700       2975                  10,8(22)              3,29(9,71)  564(705)   3277(3517)   1947        1017       Inc
                                    VEX5090S      1695       4725                 15,5(18,9)             5,98(7,94)  699(859)   3357(3677)   1947        1217       Inc
                                    VEX5100S      1250       4805                 15,9(19,7)             6,14(8,33)  841(952)   3597(3677)   2217        1217       Inc
                                    VEX5130S      1775       6110                 16,4(19,3)             6,46(8.,1)  969(1071)  3677(3837)   2217        1417       Inc
                                    VEX5160S      2410       7085                 16,3(22,9)             6,4(10,19)  1111(1284)  3837(3917)  2217        1717       Inc
                                    VEX5180S      4850       6806                   22,9                   10,19    1315(1353)    3917       2217        2017       Inc
                                   VEX5080SAF                3330                   26,4                   9,47        595        3557       1947        1017       Inc
                                   VEX5090SAF                5400                   24,4                   8,77        681        3557       1947        1217       Inc
                                   VEX5100SAF                6110                   25,2                   9,16        771        3712       2217        1217       Inc
                                   VEX5130SAF                8055                   31,6                   14,06       849        3792       2217        1417       Inc
                                   VEX5160SAF                9725                   31,6                   14,06       958        3837       2217        1717       Inc
                                   VEX5180SAF                11945                  36,1                   15,86      1102        4077       2217        2017       Inc
                                    Eventys 08     50         765        1,4                    0,17                   65         940        445         445        940
                                    Eventys 20     500       2025        4,3                    1,07                   75         940        445         445        940
                                    Eventys 30     500       2790        4,5                    1,04                   100        1040       545         545       1040
                                    Eventys 40    1000       3600        4,4                    1,03                   130        1140       645         645       1140
                                    Eventys 50    1000       4590         8                     1,79                   155        1240       745         745       1240
                                    Eventys 85    2000       7650         10                    2,31                   205        1340       970         845       1340
                                    Eventys 95    2000       9000         9                     2,11                   255        1440       1170        945       1440
                                                                                   Electric               Electric
                                                                                   Heater                 Heater

                                  Eventys 08 BE ECO  50       765        1,4        17,7        0,17       3,75        65         940        445         445        940
                                  Eventys 20 BE ECO  500     2025        4,3        20,5        1,07       11,25       75         940        445         445        940
                                  Eventys 30 BE ECO  500     2790        4,5        34,8        1,04        21         100        1040       545         545       1040
                                  Eventys 40 BE ECO  1000     3600       4,4        43,4        1,03        21         130        1140       645         645       1140



        Max/Min air volumes are calculated at 250Pa external resistance allowance.
        Units are available in flat pack for site assembly.
        Individual selection for working point can be calculated for all of the above products, contact us for more information.
   3   4   5   6   7   8   9   10   11   12